Part Number Hot Search : 
BL317 KDB3652 F0700 93LC56BP ON0942 HJ1109 IRFNJ540 MM5Z56V
Product Description
Full Text Search
 

To Download IFR6015 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Avionics
IFR 6015 Ramp Test Set
The IFR 6015 is a compact, lightweight and weatherproof unit designed for testing transponder modes A/C/S, TCAS I, II and Military E-TCAS as well as DME.
* * * * * * * * One main user screen for each test mode Detachable antenna Large display Simple user interface Lightweight and compact <8 lbs. (3.6 kg) Battery 6 hours plus duration Fully FAR part 43 appendix F compliant European Elementary and Enhanced Surveillance
The IFR 6015 features an extremely easy to use interface where every parameter the user commonly needs to view is displayed on screen. Controls Dedicated Mode keys for XPDR, DME and TCAS allow quick selection of the operational mode. The application dependant softkeys and data select/slew keys provide an intuitive man machine interface. DME mode is provided with dedicated keys for frequency/channel selection and RF level control. For frequently varied parameters in DME and TCAS modes, such as Range and Rate, dedicated keys are provided. Operational Modes Each operational mode has one main user screen. The operational modes are: XPDR (Sub-Modes: ADS-B MON, ADS-B GEN & GICB) DME TCAS 1, 2 (Sub-Modes: TIS & TIS-B) E-TCAS Most tests can be completed without leaving the main user screens. This simplifies the line technician's testing task.
For the very latest specifications visit
www.aeroflex.com
Mode S and ATCRBS Transponder Xpdr Auto-Test: Every parameter the user commonly needs to view is displayed on one screen. The auto-test performs all tests defined by FAR Part 43 Appendix F, including the proposed Eurocontrol additional tests. The tests are tailored automatically according to reported transponder level to avoid erroneous failures.
User selects config required for test. If the class of the transponder is unknown, the generic config may be selected which applies to the widest limits. The test set will automatically determine the Mode S transponder level. The selected config parameters may be displayed by pressing the INFO softkey. Eight predetermined configs are provided to meet the currently fielded transponder test needs.
The test list is selected from the auto-test screen. This provides an easy means of selecting any of the individual tests that comprise the auto-test. Tests on the 2nd screen (not shown) include: 13 UF21 14 UF24 15 ELEMENTARY SURVEILLANCE 1 16 ELEMENTARY SURVEILLANCE 2 15 ENHANCED SURVEILLANCE
The Eurocontrol Elementary Surveillance DAP's (Downlink Aircraft Parameters) are displayed on two screens
Individual tests may be reviewed for failures which are identified by an arrow symbol.
Eurocontrol Enhanced Surveillance DAP's are displayed on one screen.
No more HEX data field interpretation! All Mode S Format tests display parameter in engineering units.
TCAS TCAS types... TCAS 1 MODE C TCAS 2 ATCRBS TCAS 2 MODE S E-TCAS The Auto-Altitude feature interrogates Mode S XPDR of A/C under test to obtain current altitude. Select pre-stored named scenarios directly from the auto-test screen.
Comprehensive II / SI code and lockout timer test
ADS-B and GICB ADS-B MON: Used to monitor DF17 extended squitter from transponders and DF18 extended squitter from 1090 MHz ADS-B emitters. DME All the user needs are on one screen. * * * RF level control for track sensitivity tests Supports all DME/TACAN channels selectable in VOR paired channels Full UUT measured parameters are displayed. ADS-B GEN: Used to generate DF17/DF18 extended squitter, simulating transponders and 1090 MHz ADS-B emitters. GICB: Used to monitor DAP's (all fields).
For the very latest specifications visit
www.aeroflex.com
ADS-B MON: The ADS-B MON LIST shows BDS formats supported. The BDS status is annunciated to indicate if the squitter has been captured, not available or not seen. The BDS DATA key displays the BDS DATA screen for the selected BDS number.
ADS-B GEN: BDS DATA screens display full content of the selected BDS format in RTCA/ICAO engineering units. The NEXT & PREV PARAM keys select data fields for editing via the data slew keys.
GICB: ADS-B MON: The BDS DATA screen displays full content of selected BDS format being received via DF17, DF18 or DF19 extended squitters. The BDS LIST shows BDS formats supported. The BDS DATA key displays the BDS DATA screen for the selected BDS number.
ADS-B GEN: The BDS LIST shows BDS formats supported. The BDS SELECT key selects individual BDS numbers. The BDS ENABLE/DISABLE key enables or disables the selected BDS number for squittering via DF17 or DF18 extended squitter. The BDS DATA key displays the BDS DATA screen for the selected BDS number.
GICB: BDS DATA screens display full content of the selected BDS format being received via GICB DF20 or DF21 in RTCA/ICAO engineering units.
TIS Up to 5 static intruders may be simulated relative to the A/C (UUT).
TIS-B: The user enters the A/C (UUT) LAT/LONG and heading. Up to 5 static intruders may be simulated relative to the A/C (UUT). General Radiated Testing: The IFR 6015 is supplied with a lightweight fully sealed directional antenna that may be test set mounted, hand held or tripod mounted. Direct Connect Testing: The IFR 6015 may be directly connected to the UUT via a supplied RF coax cable via the RF I/O port.
SPECIFICATION
DME MODE SPECIFICATIONS SIGNAL GENERATOR
A 5-minute warm-up period is required for all specifications.
OUTPUT FREQUENCY
REPLY FREQUENCY Range 962 to 1213 MHz Accuracy 10 kHz
OUTPUT LEVEL
ANTENNA PORT Range -67 to -2 dBm at Antenna port Resolution 1 dB Accuracy 2 dB Distance to UUT antenna 6 to 300 ft with supplied antenna RF I/O PORT Range -115 to -47 dBm Resolution 1 dB Accuracy -95 dBm to -47 dBm Accuracy -115 dBm to <-95 dBm 2 dB 1 dB
Transit Case: The IFR 6015 is supplied in a rugged plastic transit case which provides stowage for the test set, directional antenna, RF coax cable, antenna shield, breakout box, and power supply/charger.
REPLY PULSE SPACING
P1 to P2 12 s 100 ns (X Channel) @ 50% peak P1 to P2 30 s 100 ns (Y Channel) @ 50% peak
For the very latest specifications visit
www.aeroflex.com
REPLY PULSE WIDTH
P1/P2 3.5 s 0.5 s
IDENT TONE
Selection Selectable three letter code Frequency 1350 Hz Accuracy 2 Hz
ECHO REPLY
Control On/Off Position 30 nmi 1 nmi Amplitude -11 dB 1 dB relative to reply level
UUT MEASUREMENTS ERP
Range +47 to +64 dBm Resolution 0.1 dB Accuracy 2 dB
REPLY PULSE RISE AND FALL TIMES
ALL PULSES Rise Time 2.5 s 0.25 s (10% to 90%) Fall Time 2.5 s 0.25 s (90% to 10%)
DIRECT CONNECTION PEAK PULSE POWER
Range +47 to +64 dBm Resolution 0.1 dB Accuracy 1 dB
REPLY DELAY
X CHANNEL Fixed Reply Delay 50 s 100 ns Y CHANNEL Fixed Reply Delay 56 s 100 ns
FREQUENCY
Range 1025.00 to 1150.00 MHz Resolution 10 kHz Accuracy 20 kHz
RANGE DELAY
X AND Y CHANNEL Range 0 to 450.00 nmi Resolution 0.01 nmi Accuracy 0.01 nmi
INTERROGATION PULSE WIDTH
P1 AND P2 PULSE WIDTHS Range 2.00 to 5.00 s Resolution 1 ns Accuracy 50 ns
RANGE RATE
X AND Y CHANNEL Range 10 to 6500 kts Resolution 1 kts Accuracy 0.01% typical, tested to 0.5%
INTERROGATION PULSE SPACING
P1 to P2 Spacing 10 to 14 s (X Channel) P1 to P2 Spacing 34 to 38 s (Y Channel) Resolution 10 ns Accuracy 20 ns
SQUITTER
PRF 2700 Hz Accuracy 2% Distribution Per ARINC 568
REPLY EFFICIENCY
Range 0 to 100% Resolution 1% increments Accuracy 0.5%
INTERROGATION PRF
Range 1 to 300 Hz Resolution 1 Hz Accuracy 2 Hz
TRANSPONDER MODE SPECIFICATIONS SIGNAL GENERATOR RF OUTPUT FREQUENCY
Interrogation Frequency 1030 MHz Accuracy 10 kHz
P1 to P4 10.00 s 25 ns MODE C P1 to P3 21.00 s 25 ns P1 to P4 23.00 s 25 ns
INTERROGATION PULSE WIDTHS
MODE A,C,S,INTERMODE P1,P2,P3 0.80 s 50 ns MODE S P6 (Short DPSK Block) 16.25 s 50 ns P6 (Long DPSK Block) 30.25 s 50 ns P5 0.80 s 50 ns INTERMODE P4 (Short) 0.80 s 50 ns P4 (Long) 1.60 s 50 ns
RF OUTPUT LEVEL
ANTENNA PORT MTL + 6 dB typical, automatically controlled for a MTL range of -83 to -68 dBm Range -67 to -2 dBm at antenna port Resolution 0.5 dB Accuracy 2 dB Distance to UUT antenna 6 to 200 ft with supplied antenna RF I/O PORT MTL + 6 dB typical, automatically controlled Range -115 to -47 dBm Resolution 0.5 dB Accuracy -95 to -47 dBm, 1 dB Accuracy -115 to <-95 dBm, 2 dB
INTERROGATION PULSE RISE AND FALL TIMES
ALL MODES Rise Time 50 to 100 ns Fall Time 50 to 200 ns
ATCRBS/MODE S INTERROGATION PULSE SPACING
MODE A P1 to P2 2.00 s 25 ns P1 to P3 8.00 s 25 ns MODE C P1 to P2 2.00 s 25 ns P1 to P3 21.00 s 25 ns MODE S P1 to P2 2.00 s 25 ns P1 to P6 3.50 s 25 ns P1 to SPR 4.75 s 25 ns P5 to SPR 0.40 s 50 ns
PHASE MODULATION
ALL MODES Transition Time
80 ns
Phase Shift 180 10
SLS LEVELS
ATCRBS SLS Level (P2) -9 dB, -1 to +0 dB relative to P1 level 0 dB, -0 to +1 dB relative to P1 level Off MODE S SLS Level (P5) -12 dB, -1 to +0 dB relative to P6 level +3 dB, -0 to +1 dB relative to P6 level Off Note: SLS level is automatically controlled in the SLS LEVEL test.
INTERROGATION TEST SIGNALS
MODE S PRF 50 Hz 5 Hz
INTERMODE INTERROGATION PULSE SPACING
MODE A P1 to P3 8.00 s 25 ns
For the very latest specifications visit
www.aeroflex.com
ATCRBS PRF 235 Hz 5 Hz
REPLY DELAY JITTER
ATCRBS Range 0.00 to 2.30 s Resolution 1 ns Accuracy 20 ns MODE S AND ATCRBS MODE S ALL-CALL Range 0.00 to 6.00 s Resolution 1 ns Accuracy 20 ns
UUT MEASUREMENTS ERP (@ 1090 MHZ)
Range + 45.5 to + 59 dBm (35.5 to 800 watts) Resolution 0.1 dB Accuracy 2 dB Direct Connection Peak Pulse Power (@1090 MHz) Range + 46.5 to + 59 dBm (45 to 800 watts) Resolution 0.1 dB Accuracy 1 dB
PULSE SPACING
F1 TO F2 Range 19.70 to 21.60 s Resolution 1 ns Accuracy 20 ns MODE S PREAMBLE Range, P1 to P2 0.8 to 1.2 s Range, P1 to P3 3.3 to 3.7 s Range, P1 to P4 4.3 to 4.7 s Resolution 1 ns Accuracy 20 ns
TRANSMITTER FREQUENCY
Range 1087.000 to 1093.000 MHz Resolution 10 kHz Accuracy 50 kHz
RECEIVER SENSITIVITY, RADIATED MTL
Range -67 to -79 dBm into 0 dBi antenna Resolution 0.1 dB Accuracy 2 dB, typical
RECEIVER SENSITIVITY, DIRECT CONNECTION MTL
Range -67 to -79 dBm Resolution 0.1 dB Accuracy 2 dB
PULSE WIDTHS
F1 AND F2 Range 0.25 to 0.75 s Resolution 1 ns Accuracy 20 ns MODE S PREAMBLE Range 0.25 to 0.75 s Resolution 1 ns Accuracy 20 ns
REPLY DELAY
ATCRBS Range 1.80 to 7.00 s Resolution 10 ns Accuracy 50 ns REPLY DELAY, MODE S AND ATCRBS MODE S ALL-CALL Range 125.00 to 131.00 s Resolution 10 ns Accuracy 50 ns
PULSE AMPLITUDE VARIATION
Range, Mode S (Relative to P1) +3 to -3 dB Range, ATCRBS (Relative to F1) +3 to -3 dB Resolution 0.1 dB (0.01 dB via RCI)
Accuracy 0.5 dB
F1 to C1 1.45 s 25 ns F1 to A1 2.90 s 25 ns F1 to C2 4.35 s 25 ns F1 to A2 5.80 s 25 ns F1 to C4 7.25 s 25 ns F1 to A4 8.70 s 25 ns F1 to B1 11.60 s 25 ns F1 to D1 13.05 s 25 ns F1 to B2 14.50 s 25 ns F1 to D2 15.95 s 25 ns F1 to B4 17.40 s 25 ns F1 to D4 18.85 s 25 ns MODE S P1 to P2 1.00 s 25 ns P1 to P3 3.50 s 25 ns P1 to P4 4.50 s 25 ns P1 to D1 8.00 s 25 ns D1 to Dn (n=2 to 112) 1.00 s times (n-1) 25 ns
Note 1
DF 11 SQUITTER PERIOD
Range 0.10 to 4.88 sec Resolution 10 ms Accuracy 10 ms
DIVERSITY ISOLATION
Range 0 to >20 dB (Depending on Test Distance) Test Distance 1.83m (6ft) to 28.96m (95ft) Resolution 0.1 dB Accuracy 3 dB
TCAS MODE SPECIFICATIONS SIGNAL GENERATOR OUTPUT FREQUENCY
REPLY FREQUENCY 1090 MHz Accuracy 10 kHz
OUTPUT LEVEL (SIMULATED ERP)
ANTENNA PORT Radiated power at 0dBi UUT antenna -68 dBm typical @ 10 Nmi Range, automatically controlled Range -67 to -2 dBm at Antenna port Resolution 0.5 dB Accuracy 2 dB Distance to UUT antenna 6 to 300 ft with supplied antenna RF I/O PORT Automatic mode -68 dBm @ 10 Nmi Range, automatically controlled Manual mode Range -115 to -47 dBm Resolution 0.5 dB Accuracy -95 to -47 dBm, 1 dB Accuracy -115 to <-95 dBm, 2 dB
REPLY PULSE WIDTHS
MODE C All Pulses 0.45 s 50 ns MODE S P1 through P4 0.50 s 50 ns D1 through D112 0.50 s 50 ns, 1 s chip width Reply Modes TCAS I / II Mode C (with altitude reporting) TCAS II Mode S formats 0, 11, 16 E-TCAS Modes formats 0, 4, 5, 11, 16, 20, 21
REPLY PULSE AMPLITUDES
ATCRBS 1 dB relative to F1 Mode S 1 dB relative to P1
REPLY PULSE SPACING
MODE C F1 to F2 20.30 s 25 ns
For the very latest specifications visit
www.aeroflex.com
REPLY PULSE RISE AND FALL TIMES
ALL MODES Rise Time 50 to 100 ns Fall Time 50 to 200 ns
RECEIVER
PULSE SPACING ATCRBS (Mode C All Call) S1 to P1 Accepts Rejects P1 to P3 Accepts P1 to P4 Accepts Mode S P1 to P2 Accepts P1 to SPR Accepts 2.0 us 2.0 us
200 ns 1.0 us
21.0 us
PERCENT REPLY
Range 0 to 100% Resolution 10% Accuracy 1%
200 ns 1.0 us
23.0 us
Rejects (<10% Replies)
200 ns 1.0 us
Rejects (<10% Replies)
REPLY DELAY
ATCRBS 3.0 s 50 ns Mode S 128 s 50 ns
200 ns 1.0 us
4.75 us
Rejects (<10% Replies)
200 ns 1.5 us
Rejects (<10% Replies)
RANGE DELAY
Range 0 to 260 nmi Resolution 0.1 nmi Accuracy 0.02 nmi
SUPPRESION
ATCRBS (P2 or S1) >0.5dB above level of P1 <10% Replies
UUT MEASUREMENTS
ERP (@1030MHZ)
ATCRBS Range +43 to +58 dBm (20 to 631 watts) Resolution 0.1 dB Accuracy 2 dB MODE S Range +43 to +58 dBm (20 to 631 watts) Resolution 0.1 dB Accuracy 2 dB
RANGE RATE
Range -1200 to +1200 kts Resolution 10 kts Accuracy 10%
ALTITUDE RANGE
Range -1000 to 126,000 ft Resolution, Mode C 100 ft Resolution, Mode S 25 ft
DIRECT CONNECTION PEAK PULSE POWER (@1030MHZ)
ATCRBS Range +43 to +58 dBm (20 to 631 watts) Resolution 0.1 dB Accuracy 1 dB MODE S Range +43 to +58 dBm (20 to 631 watts) Resolution 0.1 dB Accuracy 1 dB
ALTITUDE RATE
Range -10,000 to +10,000 fpm Resolution 100 fpm Accuracy 10%
SQUITTER
Control On/Off Rate 0.8 to 1.2 seconds, randomly distributed
FREQUENCY
Range 1029.900 to 1030.100 MHz Resolution 1 kHz Accuracy 10 kHz
Aging 1 ppm per year Accuracy 1 ppm Test Limit 0.3 ppm
BATTERY
Type Li Ion Duration > 4 hrs continuous operation > 6 hrs, Typical
TCAS BROADCAST INTERVAL
Range 1.0 to 12.0 sec Resolution 0.1 sec Accuracy 0.2 sec
INPUT POWER (TEST SET)
Input Range 11 VDC to 32 VDC Power Consumption 55 W Maximum 16 W Nominal at 18 VDC with charged battery Fuse Requirements 5 A, 32 VDC, Type F
MISCELLANEOUS INPUT/OUTPUTS
RF I/O Type Input/Output Impedance 50 typical Maximum Input Level 4 kW peak 10 W average VSWR < 1.3:1 ANTENNA Type Input/Output Impedance 50 typical Maximum Input Level 10 W peak 1/2 W average VIDEO Type Output Impedance 50 typical Generate Video Level 1.1 0.4V peak to peak into 50 Receive Video Level Proportional to IF level Baseline 0.5V referenced to ground
INPUT POWER (SUPPLIED EXTERNAL AC TO DC CONVERTER)
Input Range 100 to 250 VAC, 1.5 A Max, 47-63 Hz Mains Supply Voltage Fluctuations
10% of the nominal voltage
Transient Overvoltages According to Installation Category II
ENVIRONMENTAL (TEST SET)
Use Pollution Degree 2 Altitude
4800 meters
Operating Temperature
NOTE 3
-20C to 55C -30C to 71C
Storage Temperature
NOTE 4
Relative Humidity 95% 5% from 5 to 30C 75% 5% from 30 to 40C 45% 5% from 40 to 55C
ENVIRONMENTAL (SUPPLIED EXTERNAL AC TO DC CONVERTER)
Use Indoors Altitude
TEST ANTENNA
VSWR < 1.5:1 Gain 6 dB, Typical
10,000 meters
Operating Temperature 0 to 40C Storage Temperature -20C to 71C
TIME BASE (TCXO)
Temperature Stability 1 ppm
For the very latest specifications visit
www.aeroflex.com
PHYSICAL CHARACTERISTICS
DIMENSIONS Height 11.2 inches (28.5 cm) Width 9.1 inches (23.1 cm) Depth 2.7 inches (6.9 cm) Weight (Test set only) < 8 lbs. (3.6 kg)
Notes
NOTE 1 NOTE 2 NOTE 3
Simulates a 50.5 dBm XPDR ERP at 10 nMi range. Level automatically controlled based on actual distance to UUT antenna. Battery charging temperature range: 5C to 40C (controlled by internal charger). Li Ion Battery must be removed below -20C and above 60C. Temperature range extended to -20C to 55C. Temperature range reduced to -30C to 71C.
NOTE 4 NOTE 5
NOTE 6
VERSIONS AND ACCESSORIES
When ordering please quote the full ordering number information. MIL-PRF-28800F MIL-PRF-28800F MIL-PRF-28800F MIL-STD-810F MIL-PRF-28800F MIL-STD-810F MIL-PRF-28800F MIL-PRF-28800F MIL-PRF-28800F MIL-PRF-28800F MIL-PRF-28800F MIL-PRF-28800F UL-61010B-1 EN 61010-1 CSA 22.2 No 61010-1 EN 61326 Class 2 Class 2 Class 2 Method 510.4, Procedure I Class 2 Method 511.4, Procedure 1 Class 2 Class 2 Class 2 Class 2 Class 2 Class 2
SUPPLEMENTAL INFORMATION
Test Set Certifications Altitude, operating Altitude, not operating Bench Handling Blowing Dust Drip-proof Explosive Atmosphere Relative Humidity Shock, Functional Vibration Limits Temp, operating NOTE 5 Temp, not operating NOTE 6 Transit Drop Safety Compliance EMC Safety Compliance EMI/RFI Compliance EMC Drop Test
Ordering Numbers 6015-110 6015-220 6015OPT3
Versions IFR 6015 Mode A/C/S Transponder, DME, TCAS/E-TCAS, TIS and TIS-B Ramp Test Set, with US Mains Leads IFR 6015 Mode A/C/S Transponder, DME, TCAS/E-TCAS, TIS and TIS-B Ramp Test Set, with European Mains Leads ADS-B
Extended Standard Warranties with Calibration for 6015 W6015/203C Extended standard warranty 36 months with scheduled calibration W6015/205C Extended standard warranty 60 months with scheduled calibration
EXTERNAL AC-DC CONVERTER CERTIFICATIONS
UL 1950 DS CSA 22.2 No. 234 VDE EN 60 950 FCC Docket 20780 Curve "B" EN 61326 FED-STD-101C Method 5007.1 Paragraph 6.3, Procedure A, Level A Category I Method 5019 Category I Method 506.4 Procedure II of 4.1.2 Method 5009.1 Sec 6.7.1 Method 512.4
Accessories for 6015 AC0820 Desk Top Stand AC0826 Tripod AC0825CD IFR 6015 Operation Manual - CD AC24006 Tripod, Dolly, Stand EXPORT CONTROL: This product is controlled for export under the International Traffic in Arms Regulations (ITAR). A license from the U.S. Department of State is required prior to the export of this product from the United States. EXPORT WARNING: Aeroflex's military products are controlled for export under the International Traffic in Arms Regulations (ITAR) and may not be sold or proposed or offered for sale to certain countries including: Belarus, Burma, China, Cuba, Haiti, Iran, Liberia, Libya, North Korea, Somalia, Syria, Sudan, and Vietnam. See ITAR 126.1 for complete information.
TRANSIT CASE CERTIFICATIONS
Falling Dart Impact Vibration, Loose Cargo Vibration, Sweep Simulated Rainfall
ATA 300 FED-STD-101C ATA 300 MIL-STD-810F FED-STD-101C
Immersion
MIL-STD-810F
FINLAND Tel: [+358] (9) 2709 5541 Fax: [+358] (9) 804 2441 FRANCE Tel: [+33] 1 60 79 96 00 Fax: [+33] 1 60 77 69 22 GERMANY Tel: [+49] 8131 2926-0 Fax: [+49] 8131 2926-130
INDIA Tel: [+91] 80 5115 4501 Fax: [+91] 80 5115 4502 KOREA Tel: [+82] (2) 3424 2719 Fax: [+82] (2) 3424 8620 SCANDINAVIA Tel: [+45] 9614 0045 Fax: [+45] 9614 0047
SPAIN Tel: [+34] (91) 640 11 34 Fax: [+34] (91) 640 06 40 UK Burnham Tel: [+44] (0) 1628 604455 Fax: [+44] (0) 1628 662017 UK Cambridge Tel: [+44] (0) 1763 262277 Fax: [+44] (0) 1763 285353
UK Stevenage Tel: [+44] (0) 1438 742200 Fax: [+44] (0) 1438 727601 Freephone: 0800 282388 USA Tel: [+1] (316) 522 4981 Fax: [+1] (316) 522 1360 Toll Free: 800 835 2352
As we are always seeking to improve our products, the information in this document gives only a general indication of the product capacity, performance and suitability, none of which shall form part of any contract. We reserve the right to make design changes without notice. All trademarks are acknowledged. Parent company Aeroflex, Inc. (c)Aeroflex 2006.
w w w.aeroflex.com info-test@aeroflex.com
Our passion for performance is defined by three attributes represented by these three icons: solution-minded, performance-driven and customer-focused.
Part No. 46891/263, Issue 1, 01/06